Description
(2x) 755 A1 – Sold in Pair.
The Climax filter 755 A1 is designed to be used with the half masks Climax mod.755, mod. 756 and mod. 810.
The Climax filter 755 A1 is designed to be used with the half masks Climax mod.755, mod. 756 and mod. 810.
Filter against gases and vapours from chemical compounds made up of a high-density polyethylene black base fitted with a round cover made up with the same material.
Between the cover and the base there is a pre-filter with a high absorption capacity against particles.
Thread connection system (no standard).
Suitable for the retention of particles of welding fumes.
Protection Against See below:
Type A, Colour Brown: Organic gases and vapours with boiling point> 65 oC
Tests
Continuous inhaled flow resistance:
At 15 l/min: Satisfying
At 47,5 l/min: Satisfying
Protective capacity of the filter at 1000 ppm and 15 l/min against:
C6H12: Satisfying
CE Certification
Norms: EN 14387:2004+A1:2008.
Regulation (EU) 2016/425
Regulation (EU) 2016/425
Control body number: No0161
Use Limitations
This equipment should not be used in the following situations:
· Oxygen-Deficient atmospheres. (less than 19,5%)
· Immediately dangerous to life or health (IDHL)
· Immediately dangerous to life or health (IDHL)
· Unknown contaminants.
· Unknown concentrations of contaminants
Warnings
Skilled persons who have been adequately trained or who use the belt under the supervision of a competent supervisor may only use the filter 755.